Datacenter TECH racks

New Datacenter TECH racks for high density server and datacenter installations. Fully accessorized, front glass door and blind rear panel or front and rear grilled doors, 2-section blind side panels, no. 4 19’’ numbered uprights, brush strip cable entry on the base of the rack, removable trapdoors for cable inlet on the roof and the base, max loading weight till 2000 kg.

General characteristics

  • Steel sheet structure
  • Color: Grey RAL 7035 or Black RAL 9005
  • Configurations with front glass door and side and rear blind panels or front grilled door and rear grilled double door with side blind panels
  • Swing handle with key and 3- point locking system
  • Door opening 180°
  • 2-section blind side panels removable with locking key for the 42U and 47U versions; single section panels for the 27U version
  • Ventilation slits for exhaust air and holes for the installation under the roof of ventilation units
  • Brush strip cable entry on the base of rack
  • Roof and floor base panels with removable trapdoors for cable inlet
  • No. 4 19’’ uprights with unit number and adjustable in depth
  • IP20 protection degree according to EN 60529
  • Earthing kit
  • No. 4 levelling feet
  • Loading weight: 2000 Kg
  • Compliant with standard IEC 60297, EN 61587-1, EN 60917

Main features

2-section blind side and rear panels

2-section blind side and rear panels completely removable and lockable with safety key. The panels allow an easy installation and inspection procedures.

Vertical numbered uprights adj. in depth

Racks are equipped with 1 pair of numbered uprights adjustable in depth to ease the installation procedures.

Door with safety key

The door with tempered glass protects the equipment installed in the rack, swing handle with key and 3-point locking system.

Ventilation

Ventilation units with or without thermostat can be installed on all racks, zero units space take up. It can be installed without reducing the number of available units in the rack.

Compatible accessories

Plinths

Plinths to allow and protect cable pass through. The kit consists of no. 4 angle brackets and no. 4 removable flanges.

Ventilation units

Ventilation units with 2 or 4 fans, with or without thermostat, to extract air from inside the racks. Zero-unit space take up.

Vertical cable management panel

Vertical cable management panels with painted steel sheet structure complete with a snap-in cover, ideal for an easy and organized management of patch cords inside the rack.

Cable holding bracket

Cable holding bracket made of steel sheet, ideal for managing cable bundles.

Reference items

Units Height Length Depth Gray
RAL 7035
Black
RAL 9005
Front door Rear door
27U 1350 600 1000 2009128 2009128N Glassed
800 1000 2009138 2009138N Glassed
42U 2000 600 1000 2009115 2009115N Glassed
800 1000 2009171 2009171N Glassed
800 1000 2009163 2009163N Grilled Grilled double door
800 1200 2009159 2009159N Glassed
800 1200 2009164 2009164N Grilled Grilled double door
47U 2240 600 1000 2009143 2009143N Glassed
800 1000 2009134 2009134N Glassed